What are you looking for?

This is Search input need to add more information.


Overview

The new TMS 9250 Digital Telemetry Rotary Torque Measurement System, available in many different configurations to meet the needs of your particular torque measurement application. Built on Honeywell’s proven TMS digital torque platform, the TMS 9250 offers:

  • True Torque Measurement – Honeywell TMS 9250’s non-contact digital telemetry design enables higher integrity of the data capture through higher resolution and no mechanical interferences; resulting in a more accurate indication of the actual torque being experienced.
  • Flexible Modular Design – Honeywell’s modular design can easily be adapted or customized to fit into many different types of test stands to meet specific test application requirements.
  • Simple Installation, Setup, and Operation – The TMS 9250 is compact with quick attach wiring connectors for quick commissioning. It has easy to set up parameters via the software system and enables you to make test parameter adjustments on-the-fly.
  • Ongoing Reliability – Honeywell’s TMS 9250 with its non-contact design and digital telemetry solution means no friction (contact), leading to less maintenance.
  • FCC / CE Certified EMC Compliant – The TMS 9250 complies with all regulatory standards for safe RF emission standards and will not cause interference with other equipment.

  • TMS 9250 - Honeywell
    

    Documents


    Browse TMS 9250 Products

    Product Torque Range Output Torque Type Accuracy
    92511-100 100 ft-lb Voltage ±10 Vdc, sinusoidal frequency output Digital Telemetry - Non-Contact System to read 0.05% FS typical
    92511-100NM 100 Nm Voltage ±10 Vdc, sinusoidal frequency output Digital Telemetry - Non-Contact System to read 0.05% FS typical
    92511-200NM 200 Nm Voltage ±10 Vdc, sinusoidal frequency output Digital Telemetry - Non-Contact System to read 0.05% FS typical
    92511-50 50 ft-lb Voltage ±10 Vdc, sinusoidal frequency output Digital Telemetry - Non-Contact System to read 0.05% FS typical
    92512-250 250 ft-lb Voltage ±10 Vdc, sinusoidal frequency output Digital Telemetry - Non-Contact System to read 0.05% FS typical
    92512-300NM 300 Nm Voltage ±10 Vdc, sinusoidal frequency output Digital Telemetry - Non-Contact System to read 0.05% FS typical
    92512-500 500 ft-lb Voltage ±10 Vdc, sinusoidal frequency output Digital Telemetry - Non-Contact System to read 0.05% FS typical
    92512-500NM 500 Nm Voltage ±10 Vdc, sinusoidal frequency output Digital Telemetry - Non-Contact System to read 0.05% FS typical
    92513-1K 1000 ft-lb Voltage ±10 Vdc, sinusoidal frequency output Digital Telemetry - Non-Contact System to read 0.05% FS typical
    92513-1KNM 1000 Nm Voltage ±10 Vdc, sinusoidal frequency output Digital Telemetry - Non-Contact System to read 0.05% FS typical