Take advantage of microbridge mass flow sensor technology. The AWM1000 series mass flow sensor provides all of the outstanding performance benefits of the standard AWM2000 series in a more cost-effective sensor platform. This device provides accurate, repeatable flow sensing. Sensor to sensor interchangeability specifications are approximately twice as large as compared to the AWM2000 series.

The heater control circuit and the sensing bridge supply circuit are both required for operation per specification. These two circuits are not on board the sensor and must be supplied in the application. The differential amplifier circuitry may be useful in providing output gain and/or introducing voltage offsets to the sensor output.

CAUTION: PRODUCT DAMAGE

AWM Series Microbridge Mass Airflow Sensors are not designed to sense liquid flow and will be damaged by liquid flow through the sensor.
Failure to comply with these instructions could result in product damage.

Documents

TITLE DOCUMENT TYPE LANGUAGE SIZE
AWM1000 Series Airflow Sensors, Unamplified Catalog Information English 260KB
AWM Series Airflow Sensors Introduction Catalog Information English 186KB
Airflow Sensors Line Guide Product Line Guide English 132KB
Airflow, Force, and Pressure Sensors Range Guide Product Range Guide English 1MB
Sensors and Switches for Potential Use in HVAC Applications Application Note English 2MB
Sensors and Switches for Potential Medical Applications Product Range Guide English 2MB
Gas Media Compatibility and Correction Factors Technical Information English 172KB
Airflow Sensor Glossary of Terms Technical Information English 154KB
Mass Airflow Sensors Measuring Low Differential Pressures Altitude and Gas Density Correction Technical Information English 85KB
Mass Flow Sensors: Mass Flow versus Volumetric Flow and Flow Rate Unit Conversions Technical Information English 190KB
Mass Airflow Sensors Particle Contamination and Filter Manufacturers Technical Information English 99KB

Browse AWM1000 Series Products

Product Signal Conditioning Compensated Temperature Flow/Pressure Range Media Compatibility
AWM1100V Unamplified (mV) -25 °C to 85 °C [-13 °F to 185 °F] ±200 sccm Dry gas only
AWM1200V Unamplified (mV) -25 °C to 85 °C [-13 °F to 185 °F] ±10.0 mbar [4.0 in water] Dry gas only
AWM1300V Unamplified (mV) -25 °C to 85 °C [-13 °F to 185 °F] 1000 sccm (1.0 SLPM) to - 600 sccm Dry gas only